TECHNICAL ADVANTAGES
• Higher current rating, higher short Circuit Rating
(Approx. 1.2 times that of PVC).
• Thermosetting in nature.
• Higher insulation resistance _ 1000 times more than PVC cables.
• Better Resistance to Surge currents.
• Low Dielectric Losses.
• Better resistance to chemicals and corrosion.
• Longer Service life.
• Comparatively higher cable operating temperature 90° and short
circuit temperature 2500c, |
| |
COMMERCIAL ADVANTAGES
Lower laying cost because of comparatively smaller diameter of cable and lighter weight.
• Requiring less size of cable trays / supports.
• One size lower cable can be used as compared to PVC insulated
cable.
• Density of XLPE is lower than PVC
• For longer cable length voltage drop shall be considered. |
| |
SELECTION OF POWER CABLES:
Power cables are generally selected considering the application. However following factors are important for selection of suitable cable construction required to transport electrical energy from one end to the other.
(1) Maximum operating voltage.
(2) Insulation level.
(3) Frequency.
(4) Load to be carried.
(5) Possible overloading duration & magnitude.
(6) Route length and voltage drop.
(7) Mode of installation considering installation environment such as
ambient & ground temperature chemical 7 physical properties of
soil.
(8) Flame retardant properties.
(9) Plant safety Requirements.
All sizes of BHARATCAB XLPE cables are designed to standard operating conditions in India and abroad. The standards adopted are considering the geographical / climatic conditions and general applications of power for utilities, distribution and general purposes. The cables are manufactured conforming to Indian & International specification for XLPE Insulated cables. Customer specific requirements can also be met.
BHARATCAB manufacture a wide range of cables, so it is important that while placing enquiries or orders, as much information as possible should be furnished, so that the enquiries and orders are dealt quickly and efficiently. |
PARAMETERS REQUIRED ARE AS UNDER:
(1 ) Voltage Grade - 650 /]1 00 Volts
(2) Relevant Indian Standard - IS-7098 (Part-]) - 1988 or
International standard - IEC-60502 & BS-5467/DIN.
(3) Number of cores. - Single, Two, Three, Three & Half or Four Cores.
(4) Conductor - Size, wherever applicable size of reduced natural
conductor
(5) Conductor Material - Copper / Aluminium
(6) Type of Insulation - XLPE
(7) Type of Inner Sheathing -PVC Wrapped/PVC Extruded.
(8) Type of Armour - Unarmoured/Strip Armoured/Wire
Armoured/Tape Armoured
(9) Type of Outer Sheath - PVC/Flame Retardant/Flame Retardant Low
Smoke/Zero Halogen (LSOH).
(10) Length of cable required and drum lengths.
Detailed specifications are tabulated in respective catalogue. |
| Back |
|
 |
 |
|
Indian cab Corporation , 11 Takwadi , Shop No-1 , Kulbudevi Road
Opp.Edward Cinema , Mumbai - 4000 02, Maharashtra, INDIA
Contact Person :- MR. RAJ SANKLECHA
Mobile No. :- 91 9820631481
Tel. : 22088110, 22060312 * Fax : 22060312 * Email : response@indiancab.net |