PVC INSUALTED WINDING WIRES 

INDIAN - CAB Winding Wires are manufactured in an ultra-modern plant, under stringent quality control measure.
INDIAN - CAB
winding wires are insulated with a superior grade PVC compound to give it the necessary electrical
strength and resistance to abrasion.The copper conductors of required purity and conductivity are drawn and
annealed to stringent specifications.The automatic on-line controls in the extrusion process ensures consistent
high quality. 

A special range of PVC insulated winding wires with stranded copper for higher HP submersible pump motors
and for heavy duty applications such as submersible pumps used in mines, winding wires with double
insulation are also manufactured by INDIAN - CAB . 

PVC INSULATED WINDING WIRES: SOLID COPPER CONDUCTOR
(Generally as per IS: 8783 part 4, Section 1: 1995) 

Size (nom.)
mm

Dimension

Conductor resistance normally suited at 20 Deg.C 
ohms/km

Range of motors for which
HP

Conductor diameter (Min.)  mm

PVC insulation thickness(Approx.)
mm

Outside diameter
mm

0.63

0.63

0.30

1.23

56.87 Max.

2 to 3.5

0.71

0.71

0.35

1.41

44.81 Max.

2 to 3.5

0.8

0.80

0.35

1.50

35.30 Max

4 to 5

0.9

0.90

0.35

1.60

27.89 Max.

4 to 5

1.0

1.00

0.35

1.70

22.59 Max.

5to 10

1.12

1.12

0.35

1.82

17.50 Nom.

5 to 10

1.18

1.18

0.40

1.98

15.77 Nom.

10 to 20

1.32

1.32

0.40

2.12

12.60 Nom.

10 to 20

1.4

1.40

0.40

2.20

11.20 Nom.

1o to 20

1.5

1.50

0.40

2.30

9.957 Nom.

10 to 20

1.6

1.60

0.40

2.40

8.575 Nom.

20 to 30

1.7

1.70

0.40

2.50

7.596 Nom.

20 to 30

1.8

1.80

0.40

2.60

6.775 Nom.

20 to 30

1.9

1.90

0.40

2.70

6.081 Nom.

20 to 35

2.0

2.00

0.45

2.90

5.488 Nom.

20 to 35

2.12

2.12

0.45

3.02

4.884 Nom.

20 to 35

2.24

2.24

0.45

3.14

4.375 Nom

35 to 75

2.36

2.36

0.50

3.36

3.941 Nom.

35 to 75

2.5

2.50

0.50

3.50

3.512 Nom.

35 to 75

2.65

2.65

0.50

3.65

3.126Nom.

35 to 75

2.8

2.80

0.65

4.10

2.800 Nom.

Over 75

3.0

3.00

0.65

4.30

2.439 Nom.

Over 75